Home Products

IEC 60061 Standard

Good quality IEC 60065 Standard for sales
Good quality IEC 60065 Standard for sales
Our goods has safely arrived at our residence. Thank you for your excellent services. I hope we can cooperate again in the future.

—— Wira

I'm Online Chat Now

IEC 60061 Standard

(118)
China IEC60061-3: 7006-53-1 Gauge for Finished Lamps Fitted with E40 Caps for Testing Protection Against Accidental Contact factory

IEC60061-3: 7006-53-1 Gauge for Finished Lamps Fitted with E40 Caps for Testing Protection Against Accidental Contact

IEC60061-3: 7006-53-1 Gauge for Finished Lamps Fitted with E40 Caps for Testing Protection Against Accidental Contact Gauge for finished lamps fitted with E40 caps for testing protection against accidental ... Read More
2016-08-12 16:57:39
China IEC60061-3: 7006-51-2 Gauge for Caps on Finished Lamps for Testing Protect Against Accidental Contact E27/51*39 factory

IEC60061-3: 7006-51-2 Gauge for Caps on Finished Lamps for Testing Protect Against Accidental Contact E27/51*39

IEC60061-3: 7006-51-2 Gauge for Caps on Finished Lamps for Testing Protect Against Accidental Contact E27/51*39. Gauge for E27/51x39 caps on finished lamps for testing protect against accidental contact, code ... Read More
2016-08-12 16:56:16
China IEC60061-3: 7006-50-1 Gauge for Finished Lamps Fitted with E27 Caps for Testing Contact Making factory

IEC60061-3: 7006-50-1 Gauge for Finished Lamps Fitted with E27 Caps for Testing Contact Making

IEC60061-3: 7006-50-1 Gauge for Finished Lamps Fitted with E27 Caps for Testing Contact Making The drawing is intended only to illustratc the esscntial dimensions of the gauge. The gauge is shown is the test ... Read More
2016-08-12 16:39:18
China IEC60061-3: 7006-51A-2 Gauge for Caps on Finished Lamps for Testing Protect Against Accidental Contact During Insertion factory

IEC60061-3: 7006-51A-2 Gauge for Caps on Finished Lamps for Testing Protect Against Accidental Contact During Insertion

IEC60061-3: 7006-51A-2 Gauge for Caps on Finished Lamps for Testing Protect Against Accidental Contact During Insertion E27 Gauge for E27 caps on finished lamps for testing protect against accident contact ... Read More
2016-08-12 16:35:38
China IEC60061-3: 7006-27B-1 Go Gauge for E27 Caps on Finished Lamps factory

IEC60061-3: 7006-27B-1 Go Gauge for E27 Caps on Finished Lamps

IEC60061-3: 7006-27B-1 Go Gauge for E27 Caps on Finished Lamps The drawing is intended only to illustrate the essential dimensions of the gauge. The sharp part of the edge of the thread shall be broken with a ... Read More
2016-08-12 16:29:30
China IEC60061-3: 7006-28A-1 No Go Gauge for E27 Caps on Finished Lamps factory

IEC60061-3: 7006-28A-1 No Go Gauge for E27 Caps on Finished Lamps

IEC60061-3: 7006-28A-1 No Go Gauge for E27 Caps on Finished Lamps Purpose: To check the minimum outside (major) diameter of the screw thread, dimension "d" of E27 caps on finished lamps shown on sheet 7006-21. ... Read More
2016-08-12 16:27:46
China IEC60061-3: 7006-27C-1 Go Gauge for Dimension S1 of E27 Caps on Finished Lamps factory

IEC60061-3: 7006-27C-1 Go Gauge for Dimension S1 of E27 Caps on Finished Lamps

IEC60061-3: 7006-27C-1 Go Gauge for Dimension S1 of E27 Caps on Finished Lamps The plunger of the gauge is shown is the test position. When the plunger is at test, surface "W" shall be retracted deeper than ... Read More
2016-08-12 16:25:44
China B15 Lamp Cap Gauges of IEC60061-3 factory

B15 Lamp Cap Gauges of IEC60061-3

B15 Lamp Cap Gauge Include: 1) IEC60061-3 7006-11-8 B15 Go Gauges for Caps on Finished Lamps; 2) IEC60061-3 7006-10-8 B15 No Go Gauges for Caps on Finished Lamps; 3) IEC60061-3 7006-4A-2 B15d Gauges for Testing ... Read More
2016-08-12 16:23:29
China B15 Go No Go Gauge of Finished Lamp Caps factory

B15 Go No Go Gauge of Finished Lamp Caps

B15 Go No Go Gauge of Finished Lamp Caps Include: 1) IEC60061-3 7006-11-8 B15 Go Gauges for Caps on Finished Lamps; Purpose: To check dimensions A max., N min. D1 min., D1 max., and the diametrical position of ... Read More
2016-08-12 15:49:13
China B22 Lamp Cap Gauges of IEC60061-3 factory

B22 Lamp Cap Gauges of IEC60061-3

B22 Lamp Cap Gauge Include: 1) IEC60061-3 7006-11-8 B22 Go Gauge for Caps on Finished Lamps; 2) IEC60061-3 7006-10-8 B22 No Go Gauges for Caps on Finished Lamps; 3) IEC60061-3 7006-4B-1 Gauge for Testing the ... Read More
2016-08-12 15:48:10
Page 7 of 12|< 2 3 4 5 6 7 8 9 10 11 >|