—— Wira
IEC60061-3: 7006-28C-1 No Go Gauge for Caps on Finished Lamps E12Not go gauge for caps on finished lamps E12, 7006-28C-1 Purpose: To check the minimum outside (major) diameter of the screw thread, dimension d, of E12 caps on finished lamps. Testing: When the gauge is placed ... Read More
2016-08-13 11:26:06
|
IEC60061-3: 7006-27H-1 Go Gauge for Caps on Finished Lamps E12Go gauge for caps on finished lamps E12, 7006-27H-1 Purpose: To check the maximum dimensions of the screw thread and dimension T1 minimum of E12 caps on finished lamps. Testing: When the cap on a finished lamp ... Read More
2016-08-13 11:24:05
|
IEC60061-3: 7006-27F-1 Go Gauge for E14 Caps on Finished LampsGo gauge for E14 caps on finished lamps, 7006-27F-1 Purpose: To check the maximum dimensions of the screw thread and dimension T1 minimum of E14 caps on finished lamps. Testing: When the cap on a finished lamp ... Read More
2016-08-13 11:23:01
|
IEC60061-3: 7006-28B-1 No Go Gauge for E14 Caps on Finished LampsNot go gauge for E14 caps on finished lamps, 7006-28B-1 Purpose: To check the minimum outside (major) diameter of the screw thread, dimension d, of caps E14 on finished lamps. Testing: When the gauge is placed ... Read More
2016-08-13 11:21:30
|
IEC60061-3: 7006-54-2 Gauge for Finished Lamps Fitted with E14 Caps for Testing Contact MakingThe gauge is shown in the test position. In the rest position, the plunger shall be above plane V. PURPOSE: To check lamp dimensions for contact making in IEC holders. TESTING: The shape of the lamp with regard ... Read More
2016-08-13 11:20:25
|
IEC60061-3: 7006-55-2 Gauge for Finished Lamps Fitted with E14 Caps for Testing Protection Against Accidental ContactThe gauge is shown in the test position. In the rest position the plunger shall be above plane V. PURPOSE: To check protection against accidental contact. TESTING: The shape of the lamp with regard to ... Read More
2016-08-13 11:19:01
|
IEC60061-3: 7006-27G-1 Go Gauge for Dimension S1 of E14 Caps on Finished LampsGo gauge for dimension "S1" of E14 caps on finished lamps, 7006-27G-1 Purpose: To check the dimensions S1 minimum and S1 maximum of E14 caps on finished lamps. Testing: When the cap on a finished lamp has been ... Read More
2016-08-13 11:17:36
|
IEC60061-3: 7006-57-3 Go and No Go Gauge for Recessed Double Contact Cap R17d on Finished LampsIEC 60061-3 7006-57-3 Go and Not Go Gauge for Recessed Double Contact Cap R17d on Finished Lamps For details of cap R17d, see sheet 7004-56. PURPOSE: To check dimensions J min., K min., K max. and N min. of ... Read More
2016-08-13 11:14:38
|
IEC60061-3: 7006-108-2 Go and No Go Gauge for Bi-pin Bases GU4The drawing is intended only to illustrate the essential dimensions of the gauge.For details of base GU4, see sheet 7004-108. PURPOSE: To check the base GU4 in the following respects:-the diameter of the ... Read More
2016-08-13 11:11:03
|
IEC60061-3: 7006-121-1 Go No Go Gauge for bases GU10Go and not go gauge for bases GU10, 7006-121-1 Purpose: To check the base GU10 in the following respects: - the diameter of the individual pins (dimension A); - the combined displacement and diameter of the ... Read More
2016-08-13 11:07:00
|
IEC60061-3 E27 Lamp cap go gauge and no go gauges
IEC60061 B22 Go No Go Gauge of 7006-11-8 & 7006-10-8
Ipx3 Ipx4 Hand-Held Spray Nozzle
IEC 60529 Ingress Protection Test Probe Kit of Access Probes
Manufacture High Precision IEC60950 Telecom Test Probe