China IEC60061-3: 7006-10-8 B15 No Go Gauges for Caps on Finished Lamps factory

IEC60061-3: 7006-10-8 B15 No Go Gauges for Caps on Finished Lamps

Not go gauges for caps on finished lamps B15, 7006-10-8 According to standard IEC 60061-3 Purpose: To check dimension A in, of caps B15 on finished lamps. Testing: Caps on finished lamps shall be assumed to be ... Read More
2016-08-16 10:13:36
China IEC60061-3: 7006-11-8 B15 Go Gauges for Caps on Finished Lamps factory

IEC60061-3: 7006-11-8 B15 Go Gauges for Caps on Finished Lamps

According to standard IEC 60061-3 Purpose: To check dimensions A max., N min. D1 min., D1 max., and the diametrical position of the pins of caps B15 on finished lamps. Testing: The cap shall enter the gauge ... Read More
2016-08-16 10:12:28
China IEC60061-3: 7006-4A-2 B15d Gauges for Testing the Insertion of Caps in Lampholders factory

IEC60061-3: 7006-4A-2 B15d Gauges for Testing the Insertion of Caps in Lampholders

Gauges for testing the insertion of caps in lampholders B15d, 7006-4A-2 According to standard IEC 60061-3 Purpose: To check B15d cap dimensions for insertion of the cap on the finished lamp in the lampholder. ... Read More
2016-08-16 10:06:47
China IEC60061-3: 7006-4A-2 B22d Gauges for Testing the Insertion of Caps in Lampholders factory

IEC60061-3: 7006-4A-2 B22d Gauges for Testing the Insertion of Caps in Lampholders

Gauges for testing the insertion of caps in lampholders B22d, 7006-4A-2 According to standard IEC 60061-3 Purpose: To check B22d cap dimensions for insertion of the cap on the finished lamp in the lampholder. ... Read More
2016-08-16 10:05:49
China IEC60061-3: 7006-3-1 Acceptance Gauge for B22d Caps Intended for Automatic Wire Threading factory

IEC60061-3: 7006-3-1 Acceptance Gauge for B22d Caps Intended for Automatic Wire Threading

Acceptance gauge for B22d caps intended for automatic wire threading, 7006-3-1 According to standard IEC 60061-3 Purpose: To check the suitability of automatic wire threading of B22d caps as shown on sheet 7004... Read More
2016-08-13 11:49:17
China IEC60061-3: 7006-11-8 B22 Go Gauge for Caps on Finished Lamps factory

IEC60061-3: 7006-11-8 B22 Go Gauge for Caps on Finished Lamps

According to standard IEC 60061-3 Purpose: To check dimensions A max., N min. D1 min., D1 max., and the diametrical position of the pins of caps B22 on finished lamps. Testing: The cap shall enter the gauge ... Read More
2016-08-13 11:48:22
China IEC60061-3: 7006-10-8 B22 No Go Gauges for Caps on Finished Lamps factory

IEC60061-3: 7006-10-8 B22 No Go Gauges for Caps on Finished Lamps

Not go gauges for caps on finished lamps B22, 7006-10-8 According to standard IEC 60061-3 Purpose: To check dimension A in, of caps B22 on finished lamps. Testing: Caps on finished lamps shall be assumed to be ... Read More
2016-08-13 11:34:31
China IEC60061-3: 7006-4B-1 Gauge for Testing the Retention of B22d Caps in the Holder factory

IEC60061-3: 7006-4B-1 Gauge for Testing the Retention of B22d Caps in the Holder

Gauge for testing the retention of B22d caps in the holder, 7006-4B-1 According to standard IEC 60061-3 Purpose: To check cap dimensions for retention of the cap on the finished lamp in the lampholder. Testing: ... Read More
2016-08-13 11:30:01
China IEC60061-3: 7006-27A-2 Go Gauge for Caps E10 factory

IEC60061-3: 7006-27A-2 Go Gauge for Caps E10

E10 Go Gauge for caps on finished lamps according to IEC60061 7006-27A-2 The drawing is intended only to illustrate the essential dimensions of the gauge. For details of cap E10, see sheet 7004-22. The sharp ... Read More
2016-08-13 11:28:49
China IEC60061-3: 7006-27J-1 Additional Go Gauge for Caps on Finished Lamps E12 factory

IEC60061-3: 7006-27J-1 Additional Go Gauge for Caps on Finished Lamps E12

Additional go gauge for caps on finished lamps E12, 7006-27J-1 Purpose: To check the maximum outside (major) diameter, dimension d, of E12 caps on finished lamps. Testing: The gauge shall pass over the threads ... Read More
2016-08-13 11:27:23